Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Rev. bras. cir. cardiovasc ; 35(4): 427-436, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137284

RESUMO

Abstract Objective: To systematically review the rate of morbidity and mortality associated with the use of E-vita hybrid stent graft and ThoraflexTM in patients undergoing complex aortic surgery. Methods: A comprehensive search was undertaken among the four major databases to identify published data about E-vita or Thoraflex™ in patients undergoing repair of thoracic aortic aneurysms. Results: In total, 28 papers were included in the study, encompassing a total of 2,161 patients (1,919 E-vita and 242 Thoraflex™). Patients undergoing surgery with E-vita or Thoraflex™ were of similar age and sex. The number of patients undergoing non-elective repair with Thoraflex™ was higher than with E-vita (35.2% vs. 28.7%, respectively). Cardiopulmonary bypass time was associated with increasing mortality in E-vita patients, however a meta-analysis of proportions showed higher 30-day mortality, permanent neurological deficit, and one-year mortality for Thoraflex™ patients. Direct statistical comparisons between E-vita and Thoraflex™ was not possible due to heterogeneity of studies. Conclusion: Although there are limited studies available, the available data suggests that mortality and morbidity are lower for the E-vita device in thoracic aortic aneurysm surgery than for Thoraflex™. Long-term data of comparative studies do not yet exist to assess viability of these procedures.


Assuntos
Humanos , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Aorta Torácica/cirurgia , Prótese Vascular , Stents , Resultado do Tratamento
2.
Rev. bras. cir. cardiovasc ; 35(1): 58-64, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1092478

RESUMO

Abstract Objective: Cardiovascular complications in Marfan patients include progressive aortic root dilation which can precipitate acute aortic dissection, ruptured aorta, severe aortic regurgitation, or all the aforementioned. Such complications can be fatal and the cause of death prior to any surgical intervention. We set out to identify the Marfan population in England and Wales and present their surgical outcomes. Methods: A total of 306 patients with Marfan syndrome who underwent aortic root surgery were identified between April 2007 and March 2013 from NICOR database. We examined the perioperative characteristics of such cohort along with in-hospital outcomes and survival. Results: Root and ascending segment procedures on Marfan patients performed in 3.3% of the total cohort by NICOR root surgery patients. The median reported age was 40 years (IQR = 29-49 years) and 100 (32.7%) were female. Of the patients analysed, 17.3% were treated non-electively and 68.6% of them received concomitant valve procedure. The in-hospital mortality was 2.0%. Reoperation for bleeding was required in 8.2% of patients and 1.3% of them suffered a cerebrovascular accident (CVA). Mortality at 1 year was reported as 5.5%. Conclusion: The outcomes of surgery on the root and ascending aorta in Marfan patients in the United Kingdom are satisfactory; however, the overall complexities of this patient population are not well understood and would benefit from further investigations.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Intervenção Coronária Percutânea , Valva Aórtica , Reoperação , Volume Sistólico , Seguimentos , Função Ventricular Esquerda , Resultado do Tratamento , Reino Unido , Síndrome de Marfan/complicações
3.
Rev. bras. cir. cardiovasc ; 34(6): 729-738, Nov.-Dec. 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1057506

RESUMO

Abstract Aortic valve disease is one of the most common valvular heart diseases in the cardiovascular category. Surgical replacement of the diseased aortic valve remains the definitive intervention for most diseases. There is a clear consensus that in young patients who require aortic valve replacement, a mechanical prosthesis is the preferred choice due to its durable prosthesis without fear of wear and tear over time. However, this comes at the expense of increased risk of bleeding and thromboembolic events; in addition, there is a lack of strict evidence in using bioprosthesis in patients younger than 50 years. The objective of this review article is to assess the current evidence behind using bioprosthetic aortic valve in this young cohort.


Assuntos
Humanos , Adulto Jovem , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Doenças das Valvas Cardíacas/cirurgia , Desenho de Prótese , Fatores de Risco , Fatores Etários , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade
4.
Rev. bras. cir. cardiovasc ; 34(4): 464-471, July-Aug. 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1020500

RESUMO

Abstract Objective: Cerebrospinal fluid (CSF) drainage is a technique that has significantly reduced the incidence of spinal cord ischaemia (SCI). We present results of a systematic review to assess the literature on this topic in relation to thoracoabdominal aortic aneurysm repair (TAAR). Methods: Major medical databases were searched to identify papers related to CSF biomarkers measured during TAAAR. Results: Fifteen papers reported measurements of CSF biomarkers with 265 patients in total. CSF biomarkers measured included S-100ß, neuron-specific endolase (NSE), lactate, glial fibrillary acidic protein A (GFPa), Tau, heat shock protein 70 and 27 (HSP70, HSP27), and proinflammatory cytokines. Lactate and S-100ß were reported the most, but did not correlate with SCI, which was also the case with NSE and TAU. GFPa showed significant CSF level rises, both intra and postoperative in patients who suffered SCI and warrants further investigation, similar results were seen with HSP70, HSP27 and IL-8. Conclusions: Although there is significant interest in this topic, there still remains a significant lack of high-quality studies investigating CSF biomarkers during TAAR to detect SCI. A large and multicentre study is required to identify the significant role of each biomarker.


Assuntos
Humanos , Fosfopiruvato Hidratase/sangue , Biomarcadores/líquido cefalorraquidiano , Aneurisma da Aorta Torácica/cirurgia , Isquemia do Cordão Espinal/líquido cefalorraquidiano , Técnicas Eletroquímicas/métodos , Biomarcadores/sangue , Proteínas S100/líquido cefalorraquidiano , Proteínas S100/sangue , Drenagem , Ácido Láctico/líquido cefalorraquidiano , Ácido Láctico/sangue , Isquemia do Cordão Espinal/sangue
5.
Rev. bras. cir. cardiovasc ; 34(2): 213-221, Mar.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-990580

RESUMO

Abstract Objective: To investigate whether axillary artery cannulation has supremacy over innominate artery cannulation in thoracic aortic surgery. Methods: A comprehensive search was undertaken among the four major databases (PubMed, Excerpta Medica dataBASE [EMBASE], Scopus, and Ovid) to identify all randomized and nonrandomized controlled trials comparing axillary to innominate artery cannulation in thoracic aortic surgery. Databases were evaluated and assessed up to March 2017. Results: Only three studies fulfilled the criteria for this meta-analysis, including 534 patients. Cardiopulmonary bypass time was significantly shorter in the innominate group (P=0.004). However, the innominate group had significantly higher risk of prolonged intubation > 48 hours (P=0.04) than the axillary group. Further analysis revealed no significant difference between the innominate and axillary groups for deep hypothermic circulatory arrest time (P=0.06). The relative risks for temporary and permanent neurological deficits as well as in-hospital mortality were not significantly different for both groups (P=0.90, P=0.49, and P=0.55, respectively). Length of hospital stay was similar for both groups. Conclusion: There is no superiority of axillary over innominate artery cannulation in thoracic aortic surgery in terms of perioperative outcomes; however, as the studies were limited, larger scale comparative studies are required to provide a solid evidence base for choosing optimal arterial cannulation site.


Assuntos
Humanos , Masculino , Feminino , Aorta Torácica/cirurgia , Artéria Axilar/cirurgia , Cateterismo/métodos , Tronco Braquiocefálico/cirurgia , Complicações Pós-Operatórias , Cateterismo/efeitos adversos , Cateterismo/mortalidade , Resultado do Tratamento , Mortalidade Hospitalar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA